A curated catalogue of human genomic structural variation




Variant Details

Variant: esv2759877



Internal ID9635336
Landmark
Location Information
TypeCoordinatesAssemblyOther Links
Innerchr12:7704223..8471391hg38UCSC Ensembl
Innerchr12:7856819..8623987hg19UCSC Ensembl
Innerchr12:7748086..8515254hg18UCSC Ensembl
Innerchr12:7748086..8515254hg17UCSC Ensembl
Cytoband12p13.31
Allele length
AssemblyAllele length
hg38767169
hg19767169
hg18767169
hg17767169
Variant TypeCNV gain+loss
Copy Number
Allele State
Allele Origin
Probe Count
Validation Flag
Merged StatusM
Merged Variants
Supporting Variantsesv2757487, esv2758292, esv2757488
SamplesNA18998, NA18502, NA19141, NA12717, NA18621, NA19204, NA18508, NA18855, NA12236, NA19092, NA12004, NA12146, NA10857, NA12155, NA12812, NA10854, NA12762, NA18990, NA10847, NA12760, NA12752, NA18991, NA18529, NA10838, NA18981, NA11840, NA18856, NA12239, NA18555, NA18608, NA19094, NA19003, NA06991, NA12864, NA18863, NA18564, NA19140, NA12873, NA12763, NA19211, NA10860, NA18609, NA19116, NA18872, NA12154, NA07034, NA18612, NA19153, NA18577
Known GenesC3AR1, CLEC4A, CLEC4C, CLEC6A, DPPA3, FAM66C, FAM86FP, FAM90A1, FOXJ2, LINC00937, NANOG, NANOGNB, NECAP1, POU5F1P3, SLC2A14, SLC2A3, ZNF705A
MethodBAC aCGH
SNP array
AnalysisArray images were acquired using an Agilent laser scanner (Agilent Technologies, UK). Fluorescence intensities and log2 ratio values were extracted using Bluefuse software (Bluegnome Ltd).
The algorithm used to call CNVs using the 500K EA platform was developed to accurately define CNV regions using a large set of reference samples and is described in detail in a separate publication (Komura 2006). The algorithm contains three major parts: 1) Intensity pre-processing using an improved version of Genomic Imbalance Map (GIM) (Ishikawa et al. 2005), including probe selection, noise reduction, normalization, and intensity ratio adjustment based on affinity differences between alleles of a SNP, 2) CNV extraction, which identifies CNVs from all pair-wise comparisons using a modified SW-ARRAY, and 3) A copy number inference step which utilizes signal ratios and SNP information to more precisely define CNV boundaries and the copy number within each region.
PlatformAffymetrix GeneChip Early Access Mapping 500K Set Array (250K_Nsp_SNP)
Agilent
Comments
ReferenceRedon_et_al_2006
Pubmed ID17122850
Accession Number(s)esv2759877
Frequency
Sample Size270
Observed Gain37
Observed Loss12
Observed Complex0
Frequencyn/a


Hosted by The Centre for Applied Genomics
Grant support for DGV
Please read the usage disclaimer