A curated catalogue of human genomic structural variation




Variant Details

Variant: essv95575



Internal ID12611304
Landmark
Location Information
TypeCoordinatesAssemblyOther Links
Innerchr9:114323995..114324855hg38UCSC Ensembl
Outerchr9:114321935..114327995hg38UCSC Ensembl
Innerchr9:117086275..117087135hg19UCSC Ensembl
Outerchr9:117084215..117090275hg19UCSC Ensembl
Innerchr9:116126096..116126956hg18UCSC Ensembl
Outerchr9:116124036..116130096hg18UCSC Ensembl
Innerchr9:114165829..114166689hg17UCSC Ensembl
Outerchr9:114163769..114169829hg17UCSC Ensembl
Cytoband9q32
Allele length
AssemblyAllele length
hg386061
hg196061
hg186061
hg176061
Variant TypeCNV gain
Copy Number
Allele State
Allele Origin
Probe Count
Validation Flag
Merged StatusS
Merged Variantsesv33804
Supporting Variants
Samples21841
Known GenesORM1
MethodOligo aCGH
AnalysisData from the focused confirmation array were analysed using the ADM-2 algorithm at threshold 4. The ADM-2 algorithm uses log2 ratios weighted by log2 ratio error as calculated by Feature Extraction software to identify genomic intervals with copy number differences between the sample and the reference. Data were centralized, and calls with average log2 ratios less than 0.3 were excluded from the analysis, as were any calls detected by probes containing a known SNP that may alter an AluI or RsaI restriction site as determined by the 9.3 million in the UCSC annotation database for the genome browser (Karolchik D. et al. The UCSC Genome Browser Database. Nucleic Acids Res. (2003) 31:51-54.). The false-positive rate for the ADM-2 algorithm at threshold 4 was determined using three self-self hybridizations of the reference sample. In the three replicate self-self experiments, ADM-2 analysis with threshold 4 identified an average of 29.6 single-probe intervals and 10.3 multi-probe intervals. Comparing the average number of variant interval calls in self-self experiments with the average number of variant interval calls for each sample, we estimated the false-positive rate to be 0.05 (10.3/197) for multi-probe calls and 0.04 (29.6/669) for single-probe calls. The false-negative rate was estimated in a manner similar to that described by Wong et al. (Wong et al. A comprehensive analysis of common copy-number variations in the human genome. Am. J. Hum. Genet. (2007) 80:91-104.) based on four replicate experiments for one of the samples. In four replicate experiments, 223 putative variant intervals were observed two or more times and were considered true calls (49 intervals were observed twice, 43 intervals were observed three times and 131 intervals were observed four times), yielding an estimate of false-negative rate of 0.16 [(2*49+43)/(4*223)=0.16]. In this analysis, we conservatively considered aberrant intervals in two experiments the same if they overlapped by more than 0.9.
PlatformAgilent-015366 Custom Human 244K CGH Microarray
Comments
Referencede_Smith_et_al_2007
Pubmed ID17666407
Accession Number(s)essv95575
Frequency
Sample Size51
Observed Gain1
Observed Loss0
Observed Complex0
Frequencyn/a


Hosted by The Centre for Applied Genomics
Grant support for DGV
Please read the usage disclaimer